Industry solution: Healthcare
IT Security for Hospitals
Protect patient data, keep care running: find security gaps in clinical IT and connected technology before attackers use them.
Industry solution: Healthcare
Protect patient data, keep care running: find security gaps in clinical IT and connected technology before attackers use them.
Which cybersecurity obligations apply to a hospital depends on the country. At EU level, the NIS2 Directive lists healthcare providers among the sectors of high criticality. It applies to medium-sized and large entities, and Member States may also include smaller ones. Each country transposes the directive into national law, so the details differ. The table shows the EU framework and, as an example, the rules in Germany. Vulnerability management provides the technical basis for finding and documenting security gaps systematically.
| Regulation | Applies to | Key point |
|---|---|---|
| EU: NIS2 Directive (EU) 2022/2555 | Healthcare providers (Annex I), if they are medium-sized or large. Member States may include smaller entities. | Entities classed as essential or important take risk management measures for cybersecurity and report significant incidents. Each Member State transposes the directive into national law. |
| Germany: Section 391 SGB V (formerly Section 75c SGB V) | All hospitals, unless they are already obliged as operators of critical facilities under the BSI Act | Appropriate organizational and technical precautions in line with the state of the art to avoid disruptions to the availability, integrity and confidentiality of IT systems. This includes measures to raise the security awareness of staff. |
| Germany: Industry-specific security standard (B3S) | Hospitals | Developed by the German Hospital Federation (DKG); the BSI has determined its suitability. Applying it is one way to meet the legal obligation. |
| Germany: BSI Act (BSIG), in force since 6 December 2025 | Hospitals classified as important or particularly important entities, and operators of critical facilities | Risk management measures, reporting obligations for significant security incidents and registration with the BSI. |
Note: Which obligations apply to your hospital depends on the country, its size and its classification. If your hospital is in another EU country, check how that country has transposed the NIS2 Directive. In Germany, hospitals that reach or exceed the threshold of 30,000 fully inpatient cases per year count as operators of critical facilities (Annex 5 BSI-KritisV). Whether a hospital below that threshold counts as an important or particularly important entity depends on staff numbers, turnover and balance sheet total (Section 28 BSIG). Have your classification checked by legal counsel. Status of this information: November 2026. More on regulation on our NIS2 Directive page.
OPENVAS checks networks and systems for known vulnerabilities and provides the results in reports. These are the key functions at a glance.
OPENVAS BASIC is designed for networks with fewer than 150 assets. For environments with more than 150 assets, OPENVAS SCAN is intended, with Greenbone Support and an individual quote. Both products run vulnerability tests and compliance audits and start scans on a schedule.
| Criterion | OPENVAS BASIC | OPENVAS SCAN |
|---|---|---|
| Designed for | Networks with fewer than 150 assets | Environments with more than 150 assets |
| Deployment | Virtual appliance | Hardware appliance or virtual form |
| Sensors for distributed scans | Not possible | Possible, depending on the model |
| API access (GMP) | No | Yes |
| Greenbone Support | Not included, available separately | Yes |
| Price | €2,524.00 per year excl. VAT | On request, depending on your needs |
You can test OPENVAS BASIC free of charge for 14 days or order it directly. For OPENVAS SCAN, we offer a proof of concept in your environment. More on the products on our OPENVAS products page.
Talk to our team and find out which product fits your network.
Greenbone offers Professional Service packages around your OPENVAS SCAN appliance, from initial setup and a health check to the automation of recurring tasks. In a proof of concept, we test together how OPENVAS fits into your clinical IT.
Which legal requirements apply to hospital IT security?
At EU level, the NIS2 Directive covers healthcare providers as a sector of high criticality: it applies to medium-sized and large entities, and Member States may include smaller ones. The national rules differ by country. In Germany, under Section 391 SGB V (formerly Section 75c SGB V), hospitals must take appropriate organizational and technical precautions in line with the state of the art, including measures to raise the security awareness of staff. The obligation applies to all hospitals unless they are already obliged as operators of critical facilities under the BSI Act. The industry-specific security standard B3S is one way to meet this obligation. Further obligations arise under the BSI Act for hospitals classified as important or particularly important entities or as operators of critical facilities. This information is not legal advice.
When is a hospital an operator of a critical facility in Germany?
Under the German BSI-KritisV, a hospital is a critical facility when it reaches or exceeds the threshold of 30,000 fully inpatient cases per year. For all other hospitals, classification as an important or particularly important entity depends on staff numbers, turnover and balance sheet total. Check your classification with your legal department.
Can vulnerability scans affect medical devices?
An active scan sends requests to the systems it checks, so caution is needed with sensitive technology. In OPENVAS you define the scan targets yourself, can exclude individual systems and can schedule scans. Coordination with medical engineering and the device manufacturers is advisable before you include such systems.
How do I start with vulnerability management in a hospital?
First, record the systems to be scanned and define scan targets. A first scan shows which known vulnerabilities exist. Use the report to prioritize the findings, fix the gaps and repeat the scan regularly. A proof of concept makes it possible to start in your environment.
How much does OPENVAS cost?
OPENVAS BASIC costs €2,524.00 per year excl. VAT and is designed for networks with fewer than 150 assets. The price for OPENVAS SCAN depends on your needs and is quoted individually.
Can I test OPENVAS before buying?
You can test OPENVAS BASIC free of charge for 14 days. For OPENVAS SCAN, we offer a proof of concept in your environment.
Talk to our team about which solution fits your clinical IT. The consultation is free of charge.
Greenbone was founded in 2008 and develops OPENVAS on an open-source basis. The OPENVAS ENTERPRISE FEED provides regularly updated vulnerability tests. Greenbone is certified to ISO/IEC 27001, ISO 9001:2015 and ISO 14001:2015.